SIP Configuration |
Top Previous Next |
|
This allows you to configure the settings for SIP connections (Session Initiation Protocol) of
General informations about SIP can be found in chapter Necessary settings for framed connection/How to establish IP connections/IP connections.
SIP Settings dialog:
1) SIP Registration Settings
Here the SIP registration profile can be selected.
The Registrar is the SIP registration server which resolves the SIP address to a real IP address. The SIP client must register itself to a Registrar first before it can use its service. In this field an IP-address or an URL can be entered. The registration comprises the following access data: - Name
Here the name of the registration access data can be entered (max. 256 chars).
1.4 Password
Here the phone number of the registration access data can be entered (max. 256 chars). This access data is just necessary for a few registrars.
Just an active profile causes an registration. However, only an inactive profile can be changed. Therefore at a new profile first ‘Active’ must be set to false. After all registration info is entered ‘Active’ must be set to true to validate the registration.
2) Other SIP Settings
A STUN server (Simple Transversal of UDP Through NATs) is necessary that a client behind a NAT or NATs can find its public IP address. NAT stands for Network Address Translation. In this field an IP-address or an URL can be entered. This setting is optional.
Here the global proxy must be entered. The global proxy is responsible for how SIP requests and messages are handled. In this field an IP-address or an URL can be entered. This setting is optional.
|